rcp specifications

 

CAPACITY

 

 

 

 

MODEL [a]

SCFH

TERMINATION

         DIMENSIONS

WEIGHT

 

[b]

 

Diam.

Length [c]

Lbs.

RCP-10-2000-4SS

10

1/4" Swagelok

1.05

9.5

0.8

RCP-10-2000-4VCR

10

1/4" VCR

1.05

9.5

0.8

RCP-25-2200-4SS

25

1/4" Swagelok

1.32

14.5

2.4

RCP-25-2200-4VCR

25

1/4" VCR

1.32

14.5

2.4

RCP-50-1200-4SS

50

1/4" Swagelok

1.66

15

2.3

RCP-50-1200-4VCR

50

1/4" VCR

1.66

15

2.3

RCP-100-1400-4SS

100

1/4" Swagelok

2.38

15.5

6

RCP-100-1400-4VCR

100

1/4" VCR

2.38

15.5

6

RCP-200-1300-4SS

200

1/4" Swagelok

2.88

19.5

10

RCP-200-1300-6SS

200

3/8" Swagelok

2.88

19.5

10

RCP-200-1300-4VCR

200

1/4" VCR

2.88

19.5

10

RCP-200-1300-8VCR

200

1/2" VCR

2.88

19.5

10

RCP-500-900-8SS

500

1/2" Swagelok

4

23

18

RCP-500-900-8VCR

500

1/2" VCR

4

23

18

RCP-1000-800-12FF

1000

3/4" FPT

4.5

33

35

RCP-1000-800-12SS

1000

3/4" Swagelok

4.5

33

35

RCP-1000-800-12VCR

1000

3/4" VCR

4.5

33

35

RCP-2000-800-24FF

2000

1.5" FPT

5.56

42.5

60

RCP-2000-800-16SS

2000

1" Swagelok

5.56

42.5

60

RCP-3500-800-16SS

3500

1" Swagelok

6.63

51.5

100

RCP-3500-800-24FF

3500

1.5" FPT

6.63

51.5

100

RCP-5000-800-24FF

3500

1.5" FPT

8.63

44.5

175

RCP-10000-700-32FF

10000

2" FPT

10.75

56

300

RCP-20000-500-32FF

20000

2" FPT

12.75

76

460

 (a) The model number is coded to indicate capacity, maximum operating pressure and termination. Capacity is defined in terms of the maximum flow at which the unit will reduce 1% oxygen in hydrogen to 1 ppm. Terminations are coded FF for female pipe thread, SS for Swagelok compression fittings and VCR for Cajon VCR zero-clearance face seal fittings. The termination code include includes a number which indicates the size of fittings in 1/16's of an inch.

        e.g. -4SS indicates 1/4" Swagelok tube fittings, both ends. 

               -8VCR indicates 1/2" Cajon VCR face seal fittings, both ends.

               -12FF indicates 3/4" female pipe fittings, both ends.

 (b)     SCFH stands for Standard Cubic Feet per Hour

 (c)     Dimensions are in inches and Length includes fittings.

 

RSI PURIFIERS (LLC), Plant and Offices
Seven Merry Lane, East Hanover, NJ (USA) 07936
Phone: 973-884-0650 • Fax: 973-515-3166 • Email: info@rsipurifiers.com
Home | Hydrogen Purifiers | Catalytic Purifiers | Molecular Sieve Dryers | Industrial Gas Purifiers | Downloads | Contact Us